Total Sulfur by ASTM D4294 measures the total sulfur content of petroleum products by energy-dispersive X-ray fluorescence (ED-XRF) spectrometry. It covers sulfur from about 17 mg/kg (ppm) up to 4.6% by mass in liquid hydrocarbons such as mineral insulating oils, lubricating base oils, hydraulic oils, distillate fuels and crude oil. The sample is placed in the X-ray beam, which excites the sulfur atoms. The intensity of the characteristic sulfur X-rays they give off is then compared against calibration standards.
What method is used to analyze the sample?
ASTM D4294
How do you interpret the results?
Results are reported as total sulfur in mg/kg (ppm) or % by mass. The value covers every sulfur compound in the oil, corrosive or not; the test doesn’t tell the forms apart. Compare the result against the oil’s new-oil specification, the supplier’s typical values or earlier samples from the same unit. A high or rising value, or a difference from the oil originally supplied, calls for follow-up testing to find out whether corrosive forms are present. That testing includes ASTM D1275 (corrosive sulfur) and dibenzyl disulfide (DBDS) analysis.
What do the results indicate?
Corrosive sulfur should be absent from the insulating fluid in electrical equipment, or present only at levels that won’t harm the metal components, particularly copper conductors and braces. In many transformer oils, total sulfur analysis shows that the sulfur is organic and not corrosive, at levels as high as 2000 ppm. The most corrosive form is elemental sulfur itself, which is active even at low ppm levels. Total sulfur is therefore best used as a screening and baseline test. It shows how much sulfur is present and whether the oil matches its specification. It can’t show whether that sulfur is a corrosion risk, so a high or changing total sulfur result should be followed by corrosive sulfur testing.